oolBookedFree tools for HVAC pros

Leak-Rate Triggers & Repair Clocks

Triggers, deadlines, and the two coverage thresholds — 50 lb vs 15 lb.

The short answer

Cross your trigger — 10% comfort cooling, 20% commercial refrigeration, 30% industrial process, 10% everything else — and the clock starts: repair in 30 days (120 with an industrial process shutdown), or a retrofit/retire plan in 30 days, done in 1 year. Leak 125% of full charge in a calendar year and the appliance is a chronic leaker: report to EPA by March 1. Records: 3 years.

1. Which appliances are covered?

RuleRefrigerantsCoverage threshold
40 CFR §82.157 (classic Section 608)Ozone-depleting (e.g. R-22)Full charge 50 lb or more
40 CFR §84.106 (AIM Act, applies as of Jan 1, 2026)HFCs, and substitutes with GWP > 53Full charge 15 lb or more

One carve-out to memorize: residential and light-commercial AC and heat pumps are exempt from §84.106 leak repair (§84.106(a)) — venting, certification, and recovery rules still apply to them in full.

2. The trigger rates

The leak rate is annualized at every refrigerant addition — (lb added ÷ full charge) × (365 ÷ days since the last addition) × 100 — or by EPA's rolling-average method. The same method must be used for every covered appliance at a facility.

Appliance typeTrigger leak rate
Comfort cooling (chillers included)10% per year
Commercial refrigeration20% per year
Industrial process refrigeration30% per year
All other appliances10% per year

Old-key trap: pre-2016 study guides list 35% triggers. That key is retired — the table above is current under both §82.157 and §84.106.

3. The clocks, once you cross a trigger

DutyDeadline
Repair the leaks30 days from the addition that showed the exceedance
Repair requiring an industrial process shutdown120 days
Retrofit / retire insteadPlan developed within 30 days, kept on site, completed within 1 year
Verification tests after repairInitial test when the repair is finished (before refrigerant is added back); follow-up within 30 days after the appliance returns to normal operating conditions
Leak inspections after an exceedanceAnnual for most; quarterly for commercial / IPR appliances at 500 lb or more, until four consecutive quarters below the trigger
Chronic leaker (≥125% of full charge in a calendar year)Report to EPA by March 1 of the following year
RecordsKept 3 years: date, technician name + certification number, refrigerant added/recovered, leak check + method, leaks found/repaired, verification test dates

Stuck waiting on parts, or another regulation blocks the repair? EPA permits additional time in those cases — documented, not automatic. And if the appliance is mothballed (evacuated to at least atmospheric pressure and temporarily shut down), the timelines suspend until it returns to service.